What is a V-Bank Filter?
V-bank filter is a V/W type densely pleated combination air filter that arranges multiple mini-pleat filter bags in a V-shape within a frame, increasing filtration area in the same installation space. They are suitable for high-flow, high-efficiency commercial and industrial HVAC systems, widely used in AHU air conditioning units, clean ventilation systems, and provide stable filtration performance.
V-Bank Filters by Frame Material
ABS Plastic Frame V-Bank FiltersThe frame is lightweight, corrosion-resistant, and economical, making it suitable for most commercial and industrial AHU systems.
Galvanized Steel Frame V-Bank FiltersThe rigid structure is stable and well suited for filter boxes and industrial ventilation systems with high mechanical strength.
Aluminum Frame V-Bank FilterLight weight, good structural stability, corrosion resistance, convenient handling and installation.
V-Bank Filters by Filter Media
Glass Fiber V-Bank FiltersUsing glass fiber filter media, the filtration performance is usually more stable, making it suitable for high airflow systems that require continuous control of fine particulate matter.
Synthetic Fiber V-Bank FiltersIt adopts synthetic fiber filter material, which is light in weight and suitable for conventional industrial HVAC systems.
V-Bank Filters Product Features

Premium filter media and pleated design extend replacement intervals.

We can provide high-efficiency V-type air filters in different grades.

Increase the filtration area to achieve lower resistance.

Suitable for AHU and high-volume ventilation systems
V-Bank Filters Customized Services
You can provide Filtedge with the dimensions, rated airflow, filtration rating, allowable initial pressure drop, gasket location, installation direction, etc., and we will customize the product specifications for you.
You can also flexibly choose between synthetic fiber or fiberglass filter materials, and the frame can be made of ABS plastic, galvanized steel, or aluminum alloy. V-Bank Filter Quantity, Guard Mesh, Handle, Product Label, Packaging and OEM Brand Customized V-Bank Filters. Custom V-Bank Filters are your best choice.


V-Bank Filters Process
The filtration performance of V-Bank Filters depends not only on the filter media, but also directly on the pleat spacing, filter bag structure, frame strength, and seal quality. During Filtedge’s production process, the filter media is pleated into mini-pleat filter media bags, which are then assembled into V-shaped channels according to the design angle. The uniform pleat spacing helps distribute airflow and avoids increased resistance caused by local overdensity of the filter media. For bulk orders, we control production specifications to ensure consistent quality in subsequent batches, enabling us to provide you with high-quality V-Bank Filters.
Shipping Packaging for V-Bank Filters
Filtedeg’s V-Bank Filters feature multi-layer protective packaging, anti-collision strips, reinforced cardboard boxes, and plastic membranes to reduce filter media and frames from crushing, moisture, or collision damage during transportation. We also package individual products. For large-volume orders, we use pallets, corner protectors, and wrapping films for further securing to reduce the risk of movement and deformation during transportation. Filtedeg will also choose sea, air, or express shipping based on order quantity, filter size, and delivery time to ensure the goods are delivered safely to you.

What are the advantages of Filtedge V-Bank Filters as a manufacturer?


FiltEdge LLC is a U.S. company established in 2025, supported by SFFILTECH in China, established in 2006. Manufacturing support is provided through SFFILTECH in China. Confirm product specifications, available quality documents, pricing and delivery in the quotation. Certificates must be checked for the relevant entity, facility and product. Support is arranged during business hours; any on-site service or warranty terms require separate agreement.
V-Bank Filters Applications
V-Bank Filters are primarily used in high-volume HVAC and AHU systems in commercial buildings, data centers, medical facilities, laboratories, pharmaceutical and food production, and industrial manufacturing sites.

In office buildings, hotels, schools, shopping malls, and airports, HVAC systems operate for relatively long periods. Ordinary air filters have insufficient dust capacity and require frequent shutdowns and replacements. If the filter resistance increases too quickly, insufficient air supply to some areas, uneven room temperatures, and increased fan operating load may occur.
V-Bank Filters configure a larger effective filter media area within standard windward dimensions for continuously operating commercial ventilation air. Filtedg’s V-Bank Filters are your smartest choice.

In hospital treatment areas, public areas and some laboratories need to control fine particulate matter in the air while maintaining the room pressure differential. If the resistance of the air filter increases too quickly after dust accumulation, it will directly lead to problems such as decreased ventilation volume and unstable regional pressure differential.
You can select the appropriate grade of MERV 14–16 V-Bank Filters depending on the region and schedule replacement in conjunction with differential pressure monitoring. Special reminder that the ordinary MERV grade V-bank filter cannot replace the HEPA filter required in critical areas.

Data center cooling systems require a large amount of circulating air to be delivered around the clock. If the resistance of the air filter is too high, the airflow will decrease, increasing the fan load; Insufficient filtration efficiency can also cause dust to adhere to the surfaces of servers, heat exchange coils, and electronic components, affecting heat dissipation.
Filtedge For these high airflow, continuous operating conditions, V-Bank Filters can increase surface structure, increase airflow and dust capacity, and effectively reduce unnecessary resistance. Therefore, please provide our engineers with a specific explanation of your operating conditions, and we can recommend and customize the most suitable V-bank filter for you.
V-Bank Filters Technical Specifications
| Item | Specification |
| Efficiency | MERV13-16 |
| Media | Synthetic fiber / fiberglass |
| Airflow | 2000-4000m³/h(Customizable) |
| Temperature | ≤ 70°C(Customizable) |
| Frame | ABS plastic / galvanized steel / aluminum ABS |
| Size | Standard & Custom |
A V-shaped multi-chamber filter design significantly increases filtration area and airflow capacity.
In commercial HVAC systems, V-bank Filters are typically replaced every 6-12 months, but the replacement cycle is not monthly. A replacement plan should be developed based on your actual operating conditions and air filter pressure differential, site dust load, operating time, and system allowable final resistance.
The V-shaped air filter features a multi-V pleat structure, offering a larger filtration area than standard panel filters. It can handle higher airflow rates and boasts a longer service life.
The MERV13-16 V-Bank filter cannot be used as a direct substitute for a high efficiency particulate air (HEPA) filter. Filters should only be replaced if they meet the specified HEPA filtration efficiency, test standards, rated air volume, pressure loss, overall dimensions, gasket construction, and leak testing requirements. For critical application scenarios, the unit inspection report of the filter and the seal integrity of the installation housing must also be verified.